Home Automation Products
K
17
For answers to technical questions, call Leviton’s Techline at 1-800-824-3005
DECORA
®
HOME CONTROLS(DHC)
Residential Grade Network Integrity Products
DHC Network Integrity Products UR
DESCRIPTION CAT. NO.
Noise Block—The 6287 is designed for use with DHC switch modules that include a
means for connection to neutral. This device may be wired on the LOAD side of a DHC
switch module (except 6383), or on the LINE side of any fixture using an electronic ballast,
a low-voltage ballast, or any noise-generating source that does not require more than 5A
120V AC. The 6287 prevents interference generated by fixture components from interfer-
ing with DHC signals.
Rated: 5A 120V 60Hz AC only.
Plug-in Noise Filter—electrical appliances may generate “noise” that could interfere with
proper signal transmission. When the offending appliance is isolated and plugged into the
6288 Noise Filter, which is in turn plugged into a receptacle, stray noise is filtered out,
ensuring a clear signal. Color: Brown.
Rated: 5A 120V 60Hz AC only.
In-Line Noise Reducer—the 6289 Noise Reducer filters electrical “noise” and signals with
frequencies above and below the 121 kHz signal. The 6289 may be installed at the “noise”
or signal source or at the module affected by the interference. Depending on the source of
the interference, the 6289 may be wired phase to neutral or phase to phase.
DHC Powerline Carrier Test Equipment UR
Signal Strength Indicator—Measures command signal strength at individual module loca-
tions. Minimum signal strength required for proper DHC Powerline Carrier component
operation is 100mV.
6288
6289
6386
6287
SPECIFICATIONS AND FEATURES
• These devices are designed to eliminate interfer-
ence from appliances, electronic ballasts and
home electronics in order to insure top perform-
ance from DHC systems
• Backed by a Limited Two-Year Warranty
Signal Strength Indicator
• Signal strength testing equipment used to ensure
proper operation of DHC system
• Backed by a Limited Two-Year Warranty
TESTING AND CODE COMPLIANCE
• NOM Certified (#057)
• UL Listed (E-66800)
Signal Strength Indicator
• UL Listed (File #E-66800)
• NOM Certified (#057)
MATERIAL CHARACTERISTICS
Engineering Thermoplastic UL-94, V2 Rating
Operating Temperature: 32°F to 130°FMATERIAL
CHARACTERISTICS
Comentarios a estos manuales