RBS3202 Test with CMU300 and RNC/Iub SIM
1CM56_E 13 Rohde & Schwarz
Storing the measurement results
You can use the R&S CMU300 to save measurement results onto a
PCMCIA Type 3 card by means of screen shots as follows:
• Hardkey Print
• Destination: External WMF
6 Possible Measurements to Standard 3GPP TS 25.141 FDD R99 [1]
Transmitter measurements (Chapter 6)
Chapter Title Test Model and CMU
measurement menu
6.2.1 Base station maximum output
power
1, Power Meter
6.2.2 CPICH power accuracy 2, Code Domain Power
6.3 Frequency error 4, Modulation
6.4.4 Total power dynamic range 1, Power Meter
6.5.1 Occupied bandwidth 1, Spectrum
6.5.2.1 Spectrum emission mask 1, Spectrum
6.5.2.2 Adjacent channel leakage power
ratio (ACLR)
1, Spectrum
6.7.1 Error vector magnitude 4, Modulation
6.7.2 Peak code domain error 3, Code Domain Power
You can use R&S CMU300 and NH RNC/Iub Simulator in combination to
carry out the transmitter measurements mentioned with the aid of test
models 1/16, 2, 3/16 and 4.
Receiver measurements (Chapter 7)
Chapter
Title Remarks
7.2
Reference sensitivity level
RMC 12.2 kbps, PN9
Sequence
7.3 Dynamic range
Additional AWGN signal
covered by SW option
R&S CMU-K77
7.8
Verification of the internal BER
calculation
BER simulation function
covered by SW option
R&S CMU-K77
Further tests are possible with additional RF generators (interferers) and
the corresponding coupling networks.
The tables have been created to the best of our knowledge and belief and
are intended to provide optimum clarity for possible users. However, the
measurement solution providers accept no responsibility for the correct
interpretation of the measurement standard.