RBS3202 Test with CMU300 and RNC/Iub SIM
1CM56_E 2 Rohde & Schwarz
Table of Contents
1 Overview ............................................................................................. 2
2 Operating Principle ..............................................................................3
3 Hardware and Software Requirements.................................................4
Configuration of measurement components and cable: ................... 4
4 Test Setup ...........................................................................................5
5 Test Sequence.....................................................................................6
Activating the BTS ..........................................................................6
Transmitter measurements .............................................................8
Receiver test................................................................................. 11
Storing the measurement results.............................................. 13
6 Possible Measurements to Standard 3GPP TS 25.141 FDD R99 [1] .. 13
7 References ........................................................................................ 14
8 Abbreviations..................................................................................... 14
9 Additional Information........................................................................ 15
10 Ordering Information.......................................................................... 15
1 Overview
Specification 3GPP TS 25.141 FDD R99 [1] describes methods for testing
the transmission parameters (chapter 6) and reception parameters
(chapter 7) of WCDMA base stations. The expressed high flexibility of
UMTS with regard to the provision of different services imposes a
correspondingly high flexibility on the physical layer. Without special
measures, however, this would inflate testing costs enormously. Therefore
to ensure perfect comparability of measurement results and to reduce the
cost of testing, the specification committees have developed the following
test scenarios:
All transmitter measurements of the downlink (DL) signal must be
carried out using specially designated channel combinations known as
test models. Specification 3GPP FDD R99 details four test models.
BER measurements for testing the reception channel must be
performed using what is known as a reference measurement channel
(RMC). In this the pseudo random noise (PN) modulated uplink (UL)
signal is started by the transmission time interval (TTI) trigger on the
base station. The bit error ratio (BER) can be evaluated in the Node B,
the RNC or an external BER analyzer. Specification 3GPP FDD R99
details five reference measurement channels (RMC).